Permit: T01CM04320

Parcel: 113074310

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
03/20/2002 BUILDING - FINAL Approved IVRS - Inspection 0000*
03/19/2002 BUILDING - FINAL Denied IVRS - Inspection 0950*/ 1) NO CHANGE
03/18/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) SHALLOW WIRING TO ADDED OUTSIDE OUTLET, MUST BE 24" BELOW GRADE IN CONDUIT PLASTIC 18" METAL 6" OR 6" BELOW WITH GFCI CIRCUIT BREAKER AT PANEL
03/07/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) EXTEND CLEANOUTS TO GRADE 2) OUTSIDE ADDED OUTLET NOT GFCI PROTECTED WIRES TO SHALLOW 3) OUTSIDE HOSE BIB REQUIRED ANTI-SIPHON 4) SEAL GAS LOG PENETRATION 5) NO POWER KITCHEN GFCI PENSULA 6) NEED CERTIFICATES