Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM04311

Parcel: 126100620


Addresses:

4411 E HOLMES ST

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
01/03/2002 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
12/10/2001 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*/ 1) REBAR NOT IN
12/05/2001 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*/ 1) PLAN CALLS FOR 5 EACH #6 REBAR 3" FROM TOP AND BOTTOM OF FOOTER-NOT INSTALLED SEE SSE 0139 PAGE 1 OF 2