Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/15/2001 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000* |
| 11/14/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) NO WATER TEST ON PLUMBING 2) "S" STRAP NOT ALLOWED 3) NO PLANS ON SITE |
| 11/13/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) SANITARY T FITTINGS NOT ALLOWED TO BE USED IN THE HORIZONTAL POSITION 2) 2 WAY CLEANOUT CANNOT BE USED AS A DRAIN FITTING 3) TRANSITION GLUE CANNOT BE USED ON TWO FITTINGS OF A.B.S. USE A.B.S. GLUE (BLACK) 4) SHORT RADIUS 1/4 BENDS NOT ALLOWED FOR HORIZONTAL CHARGE IN FLOW 5) TUB NOT VENTED |