Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM04301
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/12/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
10/11/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) IRC CEILING JOIST SPAN TABLE (802.4(1)) ASSUMES JOISTS ARE PLACE WITH STRENGTH AXIS PERPENDICULAR TO CEILING SURFACE. MAXIMUM SPAN FOR 2 X 4 JOISTS IS 9'-2" UNDER THAT ASSUMPTION. THERE IS NO CODE PROVISION FOR FLAT FRAMING A CEILING DROP 2) FLEX DUCT MUST BE SUPPORTED ABOVE CEILING LEVEL 3) SOME LOOSE RED-HEADS 4) FIRE STOP SPACE BETWEEN DOUBLE WALLS UNDER STAIRS 5) NO PRESSURE ON WATER LINES |