Permit: T01CM04301

Parcel: 141015950


Addresses:

5253 S CIVANO BL


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM04301

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/12/2001 FRAMING Approved IVRS - Inspection 0000*
10/11/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) IRC CEILING JOIST SPAN TABLE (802.4(1)) ASSUMES JOISTS ARE PLACE WITH STRENGTH AXIS PERPENDICULAR TO CEILING SURFACE. MAXIMUM SPAN FOR 2 X 4 JOISTS IS 9'-2" UNDER THAT ASSUMPTION. THERE IS NO CODE PROVISION FOR FLAT FRAMING A CEILING DROP 2) FLEX DUCT MUST BE SUPPORTED ABOVE CEILING LEVEL 3) SOME LOOSE RED-HEADS 4) FIRE STOP SPACE BETWEEN DOUBLE WALLS UNDER STAIRS 5) NO PRESSURE ON WATER LINES