Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/29/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000*/ 1) RAFTER SPAN 2 X 10-OK PLAN CHANGE 21' BY R ARVAYO |
| 11/27/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) PLAN CALLS FOR 2 X 12'S AT 16" ON CENTER YOU HAVE 2 X 10'S |
| 10/12/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |