Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/30/2003 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*/ 1) BLDG #2 ABS DWV UNDERGROUND OK, BLDG DRAIN TIE-INS AT SEWER-OK, SEWER TO SOUTH WEST CORNER OF BLDG-OK AND WATER TEST-OK 2) OK TO COVER ALL AREAS |
| 05/29/2003 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000* |
| 05/27/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) WET VENTED SECTION TO BE ONE PIPE SIZE LARGER THAN UPPER TRAP SIZE 2) TRAP ARM MAY ONLY CHANGE DIRECTION 90 DEGREES WITHOUT ADDITIONAL CLEANOUT |