Permit: T01CM04177

Parcel: 112071740


Addresses:

2540 N TUCSON BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/30/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) PLBG. FINAL IS OK 2.) OK FOR C OF O.
10/29/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) NONE OF THE ITEMS THAT WERE NEEDED TO BE ADDRESSED HAVE BEEN CORRECTED.
10/28/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) MUST REMOVE 12" FLEX LINE FOR WATER HTR P &T DRAIN AND PROVIDE UNION IN LINE. 2.) DBL WALL FLU VENT FOR WATER HTR MUST HAVE 1" CLEANRANCE FROM COMBUSTIBLE MATERIAL 3.) MUST PROVIDE C.O. FOR KITCHEN SINK 4.) MUST CAULK EXSISTING WATER CLOSET 5.) MUST TAPE UP INSUALTION JOINTS FOR EXTERIOR WATER LINE ON NORTH WALL.