Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 09/25/2001 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*1.) ABS DWV OK WATER TEST OK 2.) CONDENSATE RAN TO LAV. TAIL PIECE. 3.) WILL CALL FOR GAS INSPECTION 4.) OK TO COVER WALLS AND CEILING. |
| 09/23/2001 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) SUPPORT LAVATORY VENT.2.) YOU MAY NOT TIE-IN YOUR CONDENSATE DRAIN INTO THE VENT ABOVE THE BATHROOM 3.) WATER TEST ABS THROUGH ROOF. 4.) GET A PERMIT FOR GAS-YOU HAVE ADDED PIPING AT THE WATER HEATER. TEST TO 10#. |
| 09/14/2001 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*1.) REDLINE "AS BUILTS" TO REFLECT INSTALLATION 2.) 3" ABS UNDERGROUND OK TIE-IN TO EXISTING OK TRANSITION FITTINGS OK 3.) ROUGH IN FOR NEW BATHROOM OK WATER TEST OK 4.) OK TO BACKFILL. |