Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/19/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/18/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) LOGS AT LEDGER 2) STRAP BEAMS TO BEAM AT GARAGE 3) CHCK FOR MISSING FIRE BLOCKING 4) H2.5 AT KITCHEN LEDGER 5) FRAME AROUND WATER HEATER FLUE AT 2ND FLOOR 6) FIRE BLOCKING WINDOWS AT 2ND FLOOR 7) CHECK ALL LEDGERS FOR POSTITIVE CONNECTORS |