Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM04161
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/09/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
11/08/2001 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) PARTIAL PENDING KITCHEN PLUMBING | |
11/06/2001 | FRAMING | Denied | IVRS - Inspection 0999*1.) SEAL WEST CLEANOUT AND REPAIR HOLE ABOVE IT 2.) SEAL PATIO LIGHT 3.) SEAL TPR VALVE DRAIN. 4.) SEAL COMBUSTION VENT IN GARAGE 5.) MESH ENTRY LID ONCE FRAMED. | |
11/02/2001 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
10/29/2001 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) ITEMS 3, 4 ABOVE NOT CORRECTED 2) OK TO INSULATE ALL EXCEPT KITCHEN PLUMBING WALL | |
10/26/2001 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
10/24/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) GAS TEST FAILED 2) NO TEST ON WATER SYSTEM 3) 6 CONSECUTIVE OVER DRILLED STUDS IN BEARING WALL CODE ALLOWES A MAXIMUM OF 2 CONSECUTIVE STUDS TO BE OVERDRILLED OR NOTCHED IF STUDS ARE DOUBLED OR STUD SHOES ARE USED PROVIDE ENGINEER APPROVAL OR CORRECTION 4) FIRE BLOCK MISSING AT TRIANGLE NOOK CEILING LEVEL 6) LOOSE RED-HEADS, WRENCH TIGHTEN ALL |