Permit: T01CM04161

Parcel: 141171110


Addresses:

10430 E CHELAN ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM04161

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/09/2001 FRAMING Approved IVRS - Inspection 0000*
11/08/2001 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) PARTIAL PENDING KITCHEN PLUMBING
11/06/2001 FRAMING Denied IVRS - Inspection 0999*1.) SEAL WEST CLEANOUT AND REPAIR HOLE ABOVE IT 2.) SEAL PATIO LIGHT 3.) SEAL TPR VALVE DRAIN. 4.) SEAL COMBUSTION VENT IN GARAGE 5.) MESH ENTRY LID ONCE FRAMED.
11/02/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*
10/29/2001 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) ITEMS 3, 4 ABOVE NOT CORRECTED 2) OK TO INSULATE ALL EXCEPT KITCHEN PLUMBING WALL
10/26/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*
10/24/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) GAS TEST FAILED 2) NO TEST ON WATER SYSTEM 3) 6 CONSECUTIVE OVER DRILLED STUDS IN BEARING WALL CODE ALLOWES A MAXIMUM OF 2 CONSECUTIVE STUDS TO BE OVERDRILLED OR NOTCHED IF STUDS ARE DOUBLED OR STUD SHOES ARE USED PROVIDE ENGINEER APPROVAL OR CORRECTION 4) FIRE BLOCK MISSING AT TRIANGLE NOOK CEILING LEVEL 6) LOOSE RED-HEADS, WRENCH TIGHTEN ALL