Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T01CM04161
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/18/2001 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
10/16/2001 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) SHEARWALL #3 AT MASTER BEDROOM NOT TRANSFERED TO TRUSS (10/DT1) 2) SHEAR PANELS AT GARAGE/LR SHEARWALL NOT PER PLAN 3) BEARING WALL BETWEEN GARAGE AND LR SHOULD EXTEND TO FRONT GABLE 4) 3 POINT BEARING TRUSSES MUST BEAR AT MIDPOINT |