Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/11/2003 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 07/08/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999* ARRIVED @ 12:25 PM. NO ANSWER. ANY QUESTIONS CALL 909-5102 |
| 06/06/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*1) WHAT ARE ALL NON CONNECTED WIRES IN SUB PANEL FOR? 2) NO POWER TO REAR GFCI OUTLET 3) INSTALL H20 HEATER ELECTRIC IN FLEX CONDUIT PUT EXPOSED ROTEX IN CONDUIT AT H20 HEATER BOX 4) GFCI NOT TRIPPING BOTH 5) INSTALL SMOKE DETECTOR 6) STOPPED INSPECTION 7) COMPLETE ALL & RECALL |