Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM04151

Parcel: 140162250


Addresses:

5130 S LINNET AV

Inspection Status: Approved

Inspection History: BUILDING PRE-SLAB

Date Description Inspector Results Comments
05/17/2002 BUILDING PRE-SLAB Approved IVRS - Inspection 0000*
03/29/2002 BUILDING PRE-SLAB Denied IVRS - Inspection 0999*/ 1) FTG SHALL BE 16" WIDE PER PAGE 16 2) STEEL MET CANNOT TOUCH THE EARTH, ELEVATE 3) PLUMBING APPROVED-HAS INPROPER VENT AT THE SHOWER AND WRONG FITTING IS USED AT THE URINAL