Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/11/2002 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000* |
| 01/07/2002 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) NO CHANGE FROM 1/3/02 INSPECTION. RAISED FLOOR OF DINING ROOM, FLOOR JOIST OK TO COVER |
| 01/03/2002 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) ROUGH PLUMBING MUST BE 12" BELOW GRADE AT EXIT OF BUILDING 2) PLUMBING IS NOT PER PLAN. BUILD TO PLAN OR HAVE ARCHITECT OF RECORD REVISE PLAN AND HAVE APPROVED BY CITY OF TUCSON 3) CAST IRON SEWER RUNNING ALONG WEST SIDE OF PROPERTY TO SHALLOW. MUST BE A MINIMUM OF 12" BELOW GRADE 4) UNDERGROUND DUCT WORK NOT PER PLAN AND COVERED WITHOUT INSPECTION |
| 11/27/2001 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000* |