Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/06/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*CRICKETS NOT NAILED
10/31/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) MISSING NAILING ON GARAGE ROOF 2) ALL EXTERIOR CORNERS DOUBLE TOP PLATES NOT CABIN TIED NEED TO BE STRAPPED 3) MISSING H2.5 AT GARAGE FRONT LEDGER 13/D-1
10/30/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ROOF EDGE PERIMETERS NOT NAILED, REMOVE CRICKETS AND NAIL 2) MISSING H2.5'S AT EACH STUD, AT LEDGERS 3) CORNERS NOT CABIN TIED, NEED TO STRAP 4) BAY WINDOW CRICKET NOT NAILED 5) MISSING ROOF NAILING THRU-OUT 6) NAIL ALL SHEAR PANEL TOPS TO ROOF DECK 7) WIND BRACES AT EACH CORNER AND 25' ON CENTER