Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/06/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000*CRICKETS NOT NAILED |
| 10/31/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) MISSING NAILING ON GARAGE ROOF 2) ALL EXTERIOR CORNERS DOUBLE TOP PLATES NOT CABIN TIED NEED TO BE STRAPPED 3) MISSING H2.5 AT GARAGE FRONT LEDGER 13/D-1 |
| 10/30/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) ROOF EDGE PERIMETERS NOT NAILED, REMOVE CRICKETS AND NAIL 2) MISSING H2.5'S AT EACH STUD, AT LEDGERS 3) CORNERS NOT CABIN TIED, NEED TO STRAP 4) BAY WINDOW CRICKET NOT NAILED 5) MISSING ROOF NAILING THRU-OUT 6) NAIL ALL SHEAR PANEL TOPS TO ROOF DECK 7) WIND BRACES AT EACH CORNER AND 25' ON CENTER |