Permit: T01CM04066

Parcel: 141112710

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM04066

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/26/2001 FRAMING Approved IVRS - Inspection 0000*
11/21/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) FIREBLOCK HOT WATER FLUE AT 2ND FLOOR CEILING 2) HOW WERE FLOOR TRUSS BRACKETS CORRECTED ?
11/19/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) STRAP TOP PLATES AT GAS PIPE HOLES 2) CORRECT FLOOR TRUSS BRACKETS NORTH OF KITCHEN SINK 3) BLOCK DUCT BOOT IN FAMILY ROOM 4) STRAP 2 X 6 TOP PLATES AT PLUMBING HOLES PLUS 2 X 4"-2ND FLOOR 5) SHIM PASS THROUGH HEADER 6) FIREBLOCK AT HOT WATER FLUE 7) NO WATER PRESSURE