Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/02/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/28/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0801*/ 1) PROVIDE 16 ON CENTER AT INTERIOR BEARING WALL |
| 09/27/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE 1" CLEARANCE FROM COMBUSTIBLE MATERIAL AT FLUE PIPE 2) SECURE POST UNDER GIRDER NAIL TOGETHER 3) DRAFTSTOP KITCHEN AREA 4) H2.5 AT JACK TRUSS IN GARAGE BEDROOM 5) A 35'S AT DOUBLE TOP PLATE NOT NAILED TO EAVE BOARD 6) BLOCK SHEARWALL IN GARAGE 7) ISOLATE PEX FROM FRAMING STRAP GARAGE |
| 09/25/2001 |
FRAMING |
|
Denied |
1) STRAP AT TOP PLATE OVER KNOTCHED AT A/C LINES 2) LOOSE A.B. THRU-OUT HOUSE 3) NAILS MISSING AT HIP HANGER 4) PROVIDE SHEARWALLS AS PER PLAN |