Permit: T01CM04056

Parcel: 138241880

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/02/2001 FRAMING Approved IVRS - Inspection 0000*
09/28/2001 FRAMING Denied IVRS - Inspection 0801*/ 1) PROVIDE 16 ON CENTER AT INTERIOR BEARING WALL
09/27/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE 1" CLEARANCE FROM COMBUSTIBLE MATERIAL AT FLUE PIPE 2) SECURE POST UNDER GIRDER NAIL TOGETHER 3) DRAFTSTOP KITCHEN AREA 4) H2.5 AT JACK TRUSS IN GARAGE BEDROOM 5) A 35'S AT DOUBLE TOP PLATE NOT NAILED TO EAVE BOARD 6) BLOCK SHEARWALL IN GARAGE 7) ISOLATE PEX FROM FRAMING STRAP GARAGE