Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/05/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/31/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SEE NOT #5 FROM INSPECTION 1/18/02 2) 2 X 4 LOOKOUT AT 24" ON CENTER NOT FRAMED |
| 01/18/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) BLOCK VENTS AT 3 SIDES 2) PROVIDE WATER IN PLUMBING FOR A TOP OUT TEST 3) PROVIDE 10 PSI AT GAS TEST 4) PROVIDE FRAMING AROUND FRONT WONDOW FOR SHEETROCK NAILING 5) MOVE SMOKE DETECTOR MINIMUM OF 3' AWAY FROM ANY VENT AT HALLWAY 6) BANG PLATES AT PLUMBING AT BATHROOM 7) DRYER VENT MUST GO THROUGH ROOF 8) PROVIDE CROSS BRACING AT MIDSPAN AT TRUSSES |