Permit: T01CM04012

Parcel: 141147200

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/09/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/08/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
10/05/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) RE-STAPLE FRONT MAIN GABLE END WHERE SHINERS ARE OVER THE RAKE RAFTER 2) LOOSE/UN-NAILED OSB AT SOUTH PLANE AT GARAGE RIDGE 3) NEED ALTERNATE H.D. AT FRONT WINDOW 4) MISSING STUD CLIPS AT ENTRY AREA AND NORTH SIDE PH22 3) RE-NAIL SHEARWALLS WHERE NAILS NOT FLUSH OR SHINERED ( REMOVE SHINERS) 6) A-35 OR H2.5 OR LAG PATIO LEDGER