Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/24/2001 FRAMING Approved IVRS - Inspection 0000*
09/21/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) A.B. MISSING AT GARAGE AND AT SLIDING DOOR 2) REMOVE SCREEN AT DRYER VENT 3) PROVIDE 1" CLEARANCE AT WATER HEATER FLUE
09/20/2001 FRAMING Partial Approval 1) PROVIDE 4 X 4 POST UNDER GIRDER BEHIND GARAGE OR LETTER FROM ENGINEER OF RECORD APPROVING CHANGE 2) PROVIDE DETAIL 6/SD2 3) PROVIDE CLEARNCE FROM COMBUSTIBLE MATERIAL AT HOT WATER PIPE 4) PROVIDE INSTRUCTION SHEET FOR INCANDESCENT LIGHT FIXTURES 5) SECURE ROMEX BEHIND PANEL WITHIN 12 INCHES 6) CORRECT AND RECALL