Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/24/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/21/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) A.B. MISSING AT GARAGE AND AT SLIDING DOOR 2) REMOVE SCREEN AT DRYER VENT 3) PROVIDE 1" CLEARANCE AT WATER HEATER FLUE |
| 09/20/2001 |
FRAMING |
|
Partial Approval |
1) PROVIDE 4 X 4 POST UNDER GIRDER BEHIND GARAGE OR LETTER FROM ENGINEER OF RECORD APPROVING CHANGE 2) PROVIDE DETAIL 6/SD2 3) PROVIDE CLEARNCE FROM COMBUSTIBLE MATERIAL AT HOT WATER PIPE 4) PROVIDE INSTRUCTION SHEET FOR INCANDESCENT LIGHT FIXTURES 5) SECURE ROMEX BEHIND PANEL WITHIN 12 INCHES 6) CORRECT AND RECALL |