Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 11/19/2001 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*PLEASE RED LINE YOUR PLANS TO NOTE DELETED LIGHTS & PLUGS AND ANY RELOCATED OR CHANGED ELECTRICAL DEVICES SUBMIT YOUR PLAN TO PLAN REVIEW DSD DOWNTOWN FOR APPROVAL.THANKS. |
| 11/13/2001 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) NOTE GARAGE CALLS FOR 2 - GFI RECEPTACLES ONLY 1 INSTALLED 2.) NOTE LIGHING ARRANGMENT IN KITCHEN HAS BEEN CHANGED INSTEAD OF SEVEN LIGHTS ONLY THREE INSTALLED 3.) FIX BROKEN 2 X 4 BLOCK ABOCE ENTRY 2 GOING SWITCH 4.) GROUND BOX AT OUTSIDE PATIO. (LIGHT). 5.) SWITCH AND LIGHT MISSING FOR OUTSIDE OF MASTER BEDROOM 6.)INSTALL FLEX FOR WTER HEATER CIRCUIT AND NAIL IT TO STUD, PROTECT AREA WHERE ROMEX ENTERS FLEX. 7.) STRAIGHTEN OUT WIRING WHERE IT ENTERS 3/4" EMT SLEEVE THUR ROOF FOR AC SO IT DOES NOT RUB AGAINTS PIPE AND NAIL. |