Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM03953

Parcel: 136153950


Addresses:

7855 E ROGET DR

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
11/19/2001 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*PLEASE RED LINE YOUR PLANS TO NOTE DELETED LIGHTS & PLUGS AND ANY RELOCATED OR CHANGED ELECTRICAL DEVICES SUBMIT YOUR PLAN TO PLAN REVIEW DSD DOWNTOWN FOR APPROVAL.THANKS.
11/13/2001 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*1.) NOTE GARAGE CALLS FOR 2 - GFI RECEPTACLES ONLY 1 INSTALLED 2.) NOTE LIGHING ARRANGMENT IN KITCHEN HAS BEEN CHANGED INSTEAD OF SEVEN LIGHTS ONLY THREE INSTALLED 3.) FIX BROKEN 2 X 4 BLOCK ABOCE ENTRY 2 GOING SWITCH 4.) GROUND BOX AT OUTSIDE PATIO. (LIGHT). 5.) SWITCH AND LIGHT MISSING FOR OUTSIDE OF MASTER BEDROOM 6.)INSTALL FLEX FOR WTER HEATER CIRCUIT AND NAIL IT TO STUD, PROTECT AREA WHERE ROMEX ENTERS FLEX. 7.) STRAIGHTEN OUT WIRING WHERE IT ENTERS 3/4" EMT SLEEVE THUR ROOF FOR AC SO IT DOES NOT RUB AGAINTS PIPE AND NAIL.