Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/25/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 01/23/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ROOF GAS PACK SUPPORT STAND NOT SECURED TO ROOF. MINIMUM REQUIRED 2 EACH 1/4" LAG SCREWS-NO DRYWALL SCREWS 2) A/C CONDENSATE BROKEN 3) ABS PLASTIC VENTS REQUIRE LATEX PAINT PROTECTION 4) FILL ALL OPEN KNOCKOUTS IN ELECTRIC SERVICE 5) NO POWER TO OUTSIDE GFCI OUTLET 6) WATER HEATER "B" VENT PLUGGED WITH TAPE 7) NO POWER TO NORTH EAST OUTLET BY EXIT DOOR 8) NO POWER TO EAST KITCHEN OUTLET |