Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/08/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 10/05/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) STRAP INSIDE AND OUTSIDE BAY TOP PLATE ANGLES 2) CORRECT A-35 INSTALL AT FRONT ENTRY LEDGER 3) STRAP TOP PLATE OF 3RD CAR WALL TO IT'S PERPENDICULAR WALL |
| 10/03/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) ALL BIRD BOARDS NOT NAILED 2) 1 ROW ROOF NAILING MISSED ON NORTH GARAGE ROOF PLANE 3) BLOCK TOP OF LEFT ENTRY COLUMN 4) BLOCK BOTTOM OF BOTH ENTRY COLUMNS 5) A.35'S IMPROPERLY INSTALLED ON FRONT ENTRY ROOF LEDGER 6) STOPPED INSPECTION AT FRONT ENTRY |
| 10/02/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |