Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/15/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 11/14/2001 |
BUILDING - FINAL |
|
Not ready for Inspection |
1) GFCI WON'T TRIP IN GARAGE 2) BUSHING MISSING AT SERVICE PANEL AND PLUG HOLE 3) NEED TO STRAP A/C FLEX, LEVEL UNIT AND STABILIZE IT 4) LABEL HEAT STRIP RATING AT ATTIC UNIT 5) WEST BATH EXHAUST FAN DOES NOT WORK 6) NEED ACCESS TO LAUNDRY CLEANOUT 7) STUCCO REPAIR AT A/C UNIT |