Permit: T01CM03889

Parcel: 134082840

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T01CM03889

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/01/2001 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*1.) REVISED & APPROVED DRAWING FOR STUDOR VENT FOR KITCHEN SINK IS OK 2.) OK FOR DRYWALL.
10/31/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0000*SEE NOTES OF 10-17
10/17/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.) WASTE & VENT SYSTEM IS OK 4.) OK FOR DRYWALL UP TO KITCHEN PONY WALL ONLY. 5.) WILL REQUIRE A REVISED & APPROVED DRAWING FOR WASTE & VENT SYSTEM FOR KITCHEN SINK BEFORE NEXT INSPECTION.
10/10/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) KITCHEN SINK WASTE NOT TO CODE OR PLAN. FRONT UNIT 2.) TUBS & SHOWER ENCLOSURES NOT INSTALLED @ THIS TIME BOTH UNITS. 3.) CLOSET RINGS NOT INSTALLED BOTH UNITS 4.) KITCHEN SINK @ REAR UNIT HAS 1 1/2" STUBB OUT AND 2" TRAP ARM. THE TRAP MUST BE THE SAME SIZE AS THE DRAIN SERVED. 5.) C.O. FOR KITCHEN SINK @ REAR UNIT MUST BE @ VERTICAL OF HORIZONTAL. AND MUST HAVE MIN 12" CLEARANCE. 6.) MUST TEST WASTE & VENT SYSTEM ALL THE WAY TO ROOF 7.) MUST SECURE ALL HORIZONTAL VENTS ABOVE CIELING.