Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T01CM03889
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/01/2001 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*1.) REVISED & APPROVED DRAWING FOR STUDOR VENT FOR KITCHEN SINK IS OK 2.) OK FOR DRYWALL. | |
| 10/31/2001 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0000*SEE NOTES OF 10-17 | |
| 10/17/2001 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.) WASTE & VENT SYSTEM IS OK 4.) OK FOR DRYWALL UP TO KITCHEN PONY WALL ONLY. 5.) WILL REQUIRE A REVISED & APPROVED DRAWING FOR WASTE & VENT SYSTEM FOR KITCHEN SINK BEFORE NEXT INSPECTION. | |
| 10/10/2001 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) KITCHEN SINK WASTE NOT TO CODE OR PLAN. FRONT UNIT 2.) TUBS & SHOWER ENCLOSURES NOT INSTALLED @ THIS TIME BOTH UNITS. 3.) CLOSET RINGS NOT INSTALLED BOTH UNITS 4.) KITCHEN SINK @ REAR UNIT HAS 1 1/2" STUBB OUT AND 2" TRAP ARM. THE TRAP MUST BE THE SAME SIZE AS THE DRAIN SERVED. 5.) C.O. FOR KITCHEN SINK @ REAR UNIT MUST BE @ VERTICAL OF HORIZONTAL. AND MUST HAVE MIN 12" CLEARANCE. 6.) MUST TEST WASTE & VENT SYSTEM ALL THE WAY TO ROOF 7.) MUST SECURE ALL HORIZONTAL VENTS ABOVE CIELING. |