Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01CM03867

Parcel: 120012100

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T01CM03867

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/30/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
08/28/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SECURE ALL DOUBLE TOP PLATES NOT CABIN TIED 2) PROVIDE DETAIL 2/A5 NOT COMPLETE MISSING HARDWARE AND NAILS THRU ROOF SHEATHIN 3) INTERIOR SHEAR TRANSFERS DETAIL 1/A3 NOT INSTALLED AS PER PLAN 4) SECURE INTERSECTION AT SHEARWALLS AS PER PLAN OR PROVIDE EQUIVALENT METHOD 5) REVISE PLAN INDICATING COMPOSET SHINGLE ROOF AND VENTING SCHEDULE TO BE USED 6) SEE TRIMMER AND KING STUD SCHEDULE SHEET A3 AND COMPLY 7) REMOVE EITHER TC CLIP OR H2.5 FROM TRUSS AS PER PLAN NAIL TC CLIPS AS PER SPECIFICATIONS