Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/30/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 08/28/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) SECURE ALL DOUBLE TOP PLATES NOT CABIN TIED 2) PROVIDE DETAIL 2/A5 NOT COMPLETE MISSING HARDWARE AND NAILS THRU ROOF SHEATHIN 3) INTERIOR SHEAR TRANSFERS DETAIL 1/A3 NOT INSTALLED AS PER PLAN 4) SECURE INTERSECTION AT SHEARWALLS AS PER PLAN OR PROVIDE EQUIVALENT METHOD 5) REVISE PLAN INDICATING COMPOSET SHINGLE ROOF AND VENTING SCHEDULE TO BE USED 6) SEE TRIMMER AND KING STUD SCHEDULE SHEET A3 AND COMPLY 7) REMOVE EITHER TC CLIP OR H2.5 FROM TRUSS AS PER PLAN NAIL TC CLIPS AS PER SPECIFICATIONS |