Permit: T01CM03859

Parcel: 10408095A

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Permit Number - T01CM03859

Inspection Description - PLUMBING - SEWER HCS CONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
01/30/2003 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection 0000*
07/16/2002 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*TEST TO M.H. OK WILL NEED VARIFICTION OF GRADE & ALL CO TO GRADE ON SEWER.
07/08/2002 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*REVISED PLAN APPROVED AS OF 6/5/02. TEST ON SITE SEWER IT BRANCHES OK AT THIS TIME. OK TO BACKFILL SUBJECT TO VARIFICATION OF GRADE. PROVIDE ACCESS TO BACKWATER VALVE INSTALL CO AT SAND & OIL TANK.
07/03/2002 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection 0000*FIX JOINTS #17-33 LEAK.
06/28/2002 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection 0000*NO TEST.
06/27/2002 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection 0000*
06/26/2002 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection 0000*NO APPROVED REVISED PLAN ON JOB FOR SITE SEWER PLEASE PROVIDE APPROVED STAMP ON JOB AT TIME OF NEXT INSP.
05/30/2002 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*SAND & SOIL ONLY.
05/09/2002 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection 0000* ALTERNATE MATERIALS AND METHODE APPEAL TO THE BUILDING OFFICAL FOR DESIGN AND ALTERNATE MATERIALS FOR SPECIAL CONDITIONS THAT OUR NOT LISTED IN THIS CODE. PLEASE PROVIDE APPROVED APPEAL AT TIME OF NEXT INSP PLEASE PROVIDE APPROVED REVISED PLANS AS NEEDED.
05/08/2002 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*94 UPC 708.0 4" OR HANGER NOT LESS THEN 1/8 INCH PER. FOOT ON 1 PERCENT. SEE PIMA COUNTY 4.4 % 6" OR LARGER STATE 4.0%. SIZE OF WASTE LINE NOT ON PLAN WEST SIDE OF BLDG. & SOUTH SIDE OF BLDG. SITE PLAN PLUMBING FLOOR PLANS CALLS FOR 4" NO SPEC ON PIPE PLEASE PROVIDE REVISED PLAN VARIFICATION OF GRADE CONTRACTOR WILL TEST AT LATER DATE.
03/14/2002 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000* APROX 52' 8" SDR 35 FROM M-H PLEASE PROVIDE VARIFICATION IF GRADE CONTRACTOR WALL PROVIDE AIR TEST AT LATER DATE.
03/13/2002 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*M-H IN STREET 13'O" INSTALLED OK TO BACKFILL WILL REQUIRE VARIFICATION OF GRADE CONTRACTOR WILL AIR TEST AT LATER DATE.