Permit: T01CM03859

Parcel: 10408095A

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T01CM03859

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/14/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
12/19/2002 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*1.) RECEPTICALS TO BE WEATHER PROOF WHEN PLUGED IN 410-57.
2.) MAINTAIN WORKING CLEARENCES FOR CAR WASH & POLISHER CONTROL PANEL & DISCONNECTS.
3.) PLEASE VERIFY LISTING FOR CAR WASH AS AN ASSEMBLY WE ONLY HAVE COMPONEST AND CONTROL CABINETS.
4.) PVC CONDUIT ON FLOOR TO BE PROTECTED.
10/10/2002 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*FINISH #1 & 2 OF PREVIOUS INSPECTION OK ROOM #27 TO OCCUPY OK LIFTS.
09/17/2002 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*FINISH INSTALLATION OF AIR TERMANALES 2.) PLEASE VERIFY LISTING OF EXHAUST FAN, CAR WASH EQUIPMENT, 3.) FINISH INSTALLATION OF LIFTS 4.) OK TEMP C OF O SUBJECT TO OTHER INSPECTION.
09/13/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0999*1. OPEN JUNCTION BOX WITH EXPOSED CONDUCTORS.
2. PROTECT SEAL TITE FROM SHARP EDGES.
3. HEATERS DO NOT CORALATE TO CHART ON STARTER.
4. VERIFY LISTING FOR EXHAUST FAN.
5. WE HAVE LOOSE TITE FITTINGS.
6. MAINTAIN WORKING SPACE CLEARANCES AT A/C DISCONNECT.
7. FINISH AIR TERMINALS AND LIGHTING ELECTRODE SYSTEM.
8. BOND COMPRESSOR DISCONNECT ENCLOSURES AND INSTALL FUSES.
9. CENTER CONDUCTORS IN PACKING OF SEALS.
10. SEAL UNUSED OPENINGS AT PANEL P-2.
11. USE AN APPROVED FITTING AT LB. CHASE NIPPLE NOT APPROVED.
12. LOOSE OFFICE FURNITURE CONNECTIONS.
09/12/2002 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*