Permit: T01CM03829

Parcel: 125151040

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM03829

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/22/2002 FRAMING Approved IVRS - Inspection 0000*
05/20/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE NAIL/SCREW PROTECTION FOR ALL PLUMBING WITHIN 1 1/4" OF STUD SURFACE 2) SHEATHING WIRES MUST EXTEND INTO ELECTRIC BOXES AT LEAST 1/4" 3) SECURE WIRES AT 4' ON CENTER 4) FIRE BLOCK BY BREAK THRU 5) BATH VENT OUTSIDE OF WALL CAVITY 6) PROVIDE WHOLE HOUSE DWV WATER TEST PER UPC 712.2 7) HEADERS MUST BEAR ON TRIMMERS 8) FIRE STOP FLOOR PENETRATIONS 2ND FLOOR 9) FIRE BLOCK ALL DROP CEILING 10) CLOSET LIGHTS MUST BE 12" IN FRONT OF SHELFS 11) NO PLANS ON SITE, STOPPED INSPECTION
05/08/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) SHEAR CHANGE ON A-6 REQUIRED CITY OF TUCSON STAMP