Permit: T01CM03818

Parcel: 140160010


Addresses:

1880 E IRVINGTON RD


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T01CM03818

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
02/04/2002 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*
02/01/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*COLUMNS & IL SMALL COLUMNS
01/31/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*TOW MAIN BLD.
01/29/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*1.) RANDOM VERTICALS ON EAST WALL HAVE LAP SPLICES FROM 32" TO 40". 40" REQUIRED PER PLAN. PLEASE PROVIDE STAMPED RFI TO ALLOW FOR APPROX 30% OF SPLICES TO BE SHORTER. 2.) EAST END OF SOUTH WALL LAP SPLICES ARE ONLY 35." 3.) WEST 1/2 OF NORTH WALL LAP SPLICES ARE 32"
01/28/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*18' COL IN FRONT.
01/25/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*CLARIFY DETAIL FOR #5 STRAPS DETAIL #204 ETC.
01/24/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*PARTIAL 9' WEST, 12' EAST, 9' SOUTH; 12' NORTH.
01/23/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*1.) PROVIDE 24" MIN EXTENSION EITHER SIDE OF M2 HEADER ON SOUTH WALL.
01/22/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*4'-8' NE; 4' S W.
01/18/2002 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection 0000*PREGROUT 1.) VERTICALS NOT YET IN PLACE. 2.) BLOCK OK.
12/19/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*PARTIAL STEM WALL BLDG OK