Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T01CM03786
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/03/2001 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
10/02/2001 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION NEED UP DATED TRUSS DRAWINGS 2) WIND BRACING REAR WALL | |
09/28/2001 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/ 1) NEED TRUSS DRAWINGS 2) NEED SHEAR ENGINEER | |
09/27/2001 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) MISSING ROOF NAILING FRONT PORCH GABLE 2) MISSING GABLE END (VERTICAL WALL NAILING FRONT GABLE 3) NORTH GABLE END OSB NOT NAILED 4) NEED TRUSS DRAWINGS 5) SHEAR PANELS NOT INSTALLED, IF NOT NEEDED, NEED ENGINEER DIRECTIONS 6) TRUSSES FOR FRONT PORCH GABLE, NEED BLOCKS FOR BEARING AT GARAGE ROOF (ENTIRE PORCH GABLE NEEDS TO BE STRAPED TO A WALL TIED TO THE FOUNDATION 7) MISSING WIND BRACING REAR WALL 8) FRONT ARCH AT PORCH NEEDS TO BE BRACED, CEILING MATERIAL IS LATH ONE COAT STUCCO |