Permit: T01CM03748

Parcel: 122050180


Addresses:

2225 N BELVEDERE AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/16/2002 FRAMING Approved IVRS - Inspection 0000*
05/14/2002 FRAMING Partial Approval IVRS - Inspection 0000*
05/03/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE PROOF OF ADEQUATE FOUNDATION UNDER AZ ROOM WEST WALL 2) HEADERS MUST BEAR ON TRIMMER STUDS 3) H2.5 CLIPS CANNOT BE SECURED WITH DRYWALL SCREWS. TELO NAILS AND 16D NAILS ONLY 4) 6 X 6 POST BASE NOT NAILED 5) PROVIDE APPROVED DETAIL FOR BEAM SADDLE CONNECTIONS TO MASONRY WALL 6) RAFTERS MISSING H2.5 CLIPS 7) WEST WALL REQUIRES 1/2" ANCHOR BOLTS 3/8" INSTALLED 8) STOPPED INSPECTION, TOO MANY ITEMS