Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/16/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 05/14/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000* |
| 05/03/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE PROOF OF ADEQUATE FOUNDATION UNDER AZ ROOM WEST WALL 2) HEADERS MUST BEAR ON TRIMMER STUDS 3) H2.5 CLIPS CANNOT BE SECURED WITH DRYWALL SCREWS. TELO NAILS AND 16D NAILS ONLY 4) 6 X 6 POST BASE NOT NAILED 5) PROVIDE APPROVED DETAIL FOR BEAM SADDLE CONNECTIONS TO MASONRY WALL 6) RAFTERS MISSING H2.5 CLIPS 7) WEST WALL REQUIRES 1/2" ANCHOR BOLTS 3/8" INSTALLED 8) STOPPED INSPECTION, TOO MANY ITEMS |