Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/24/2001 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000* |
| 12/21/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0935*/ 1) REVERSE PITCH ON FIRST AND SECOND FLOOR DRAINS 2) KITCHEN DRAIN COVERED WITHOUT INSPECTION (EXPOSE) |
| 12/19/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) PLUMBING LAYOUT IS PER PLAN BUT UNSUPORTED, KITCHEN LINE HAS REVESE PITCH 2) ALL ROUGH PLUMBING IS BRIDGED-NOT ALLOWED. SUPPORT ALL DRAIN LINES ON COMPACTED SOIL. DO NOT COVER LINES. CALL FOR RE-INSPECTION |
| 12/06/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) ALL GROUND FLOOR FIXTURES ARE BELOW THE UPSTREAM MAN HOLE AND WILL BE REQUIRED TO BE PROTECTED BY AN ACCESSIBLE BACK WATER VALVE 2) PLUMBING LAYOUT IS NOT PER PLAN |
| 12/05/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE A PLAN WITH THE LOCATION AND ELEVATION OF THE UPSTREAM SEWER MAN HOLE AND DIRECTION OF SEWER FLOW AS WELL AS THE FINISHED FLOOR ELEVATION OF THE GUEST HOUSE AND FLOOD RIM ELEVATION OF ALL FIXTURES 2) SUPPORT ALL ABS PLUMBING ON COMPACTED SOIL PRESENTLY REVERSE FLOW ON W/C NOTE: FOUNDATION IS BELOW GRADE PROVIDE GRADING PLAN FOR DISPERSAL OF GROUND WATER |
| 11/30/2001 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) SOIL LINES LOOK TO BE LOWER THAN HCS AT STREET EXCAVATION 2) SEWER LINE NOT COMPLETE, ALL PIPING NOT INSTALLED 3) PER PLAN FIXTURE LAYOUT IS FLOPPED 4) YOU HAVE A BACKWATER VALVE ISSUE MAYBE A EJECTOR PUMP ISSUE ? 5) FOR THIS INSTPECTION: ALL PIPING TO BE INSTALLED WITH PROPER PITCH, SHADED AND WATER TEST |