Inspection Status: Denied
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/21/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) SERVICE PANEL DOUBLE LUG WIRES MUST BE OF SAME SIZE AND TYPE 2) "NON WATER BOND" LABEL REQUIRED ON SERVICE DEAD FRONT 3) BOND GAS LINE 4) INSTALL THREADED CLEANOUT CAPS AND TRIM GRADE 5) FILL TRENCH 6) PROVIDE RETAIN AND GRADE 7) BARE BULB LIGHT FIXTURE NOT ALLOWED IN CLOSET 8) DRYER REQUIRES 4 WIRE OUTLET 9) OPENINGS IN RISER CANNOT EXCEED 4" PER IRC R314.2.1 |
| 05/16/2002 |
BUILDING - FINAL |
|
Cancelled |
IVRS - Ri canceled |