Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/27/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 08/20/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) WOOD LENTAL NOT ALLOWED TO SUPPORT MASONARY OVER 40 DOOR SEE NOTE 6 |
| 08/15/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) ITEMS ABOVE CORRECTED 2) CALL IN ALL INTERMEDIATES AFTER ALL TRADES COMPLETED |
| 08/13/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) STAIRS CANNOT HAVE MORE THAN 7 1/2" RISE OR MORE THAN 3/8" DEVIATION BETWEEN ANY/ALL IN RISE 2) TOP STEP NOT IN PLAIN OF PORCH 3) UNTREATED WOOD UNDER PORCH NOT ALLOWED IN CONTACT WITH CONCRETE |