Permit: T01CM03728

Parcel: 141111110

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM03728

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/05/2001 FRAMING Approved IVRS - Inspection 0000*
11/02/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) ADD 1 MORE KING AT RIGHT GARAGE 4 X 4 (OVERNOTCHED AND UNDERCUT) 2) DRYER VENT HAS FEMALE/MALE AT EXTERIOR WALL 3) FIRESTOP CHIMNEY AT 2ND FLOOR CEILING
11/01/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*
10/31/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) MISSING 4 X 4'S UNDER GIRDER TRUSS IN GARAGE 2) BLOCK DUCT BOOT IN ROOM BEHIND GARAGE AND ALL THE REST 3) REPAIR DRYER VENT DUCT CONNECTION AT EXTERIOR WALL 4) SUPPORT STAIR PLATFORM LEDGERS 5) SHIM HEADERS 6) DOUBLE KING STUD AT KITCHEN VENT 7) STRAP NON-CABIN TIED PLATES AT 1ST FLOOR 8) NAIL RAILING CABIN TIES 9) FINISH FIRE STOP AT CHIMNEY AND DUCT