Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM03728
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/05/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
| 11/02/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) ADD 1 MORE KING AT RIGHT GARAGE 4 X 4 (OVERNOTCHED AND UNDERCUT) 2) DRYER VENT HAS FEMALE/MALE AT EXTERIOR WALL 3) FIRESTOP CHIMNEY AT 2ND FLOOR CEILING | |
| 11/01/2001 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
| 10/31/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) MISSING 4 X 4'S UNDER GIRDER TRUSS IN GARAGE 2) BLOCK DUCT BOOT IN ROOM BEHIND GARAGE AND ALL THE REST 3) REPAIR DRYER VENT DUCT CONNECTION AT EXTERIOR WALL 4) SUPPORT STAIR PLATFORM LEDGERS 5) SHIM HEADERS 6) DOUBLE KING STUD AT KITCHEN VENT 7) STRAP NON-CABIN TIED PLATES AT 1ST FLOOR 8) NAIL RAILING CABIN TIES 9) FINISH FIRE STOP AT CHIMNEY AND DUCT |