Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/19/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
03/14/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SECURE ROMEX CHECK THRU-OUT 2) BOTTOM PLATED REQUIRE TO BE TREATED 3) 1" CLEARANCE AT FLUE FROM COMBUSTIBLE 4) COMPLETE FRAMING AT BATH 5) PROVIDE KING STUD AT SLIDER 6) EDGE NAILING AT SHEAR
03/08/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
01/07/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NOT PER PLAN-RAFTERS SET BACK 2 X 10'S, RIDGE SET BACK 2 X 10'S 2) HEADERS AT REAR FRONT OPENING ARE INCORRECT 3) MISSING PHAD'S AT REAR (2) 4) 7/4 NOT AS BUILT