Permit: T01CM03711

Parcel: 11712098A


Addresses:

1 S CHURCH AV #2015


Inspection Status: Approved

Inspection History: PLUMBING - ABOVE CEILING

Permit Number - T01CM03711

Inspection Description - PLUMBING - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
09/23/2001 PLUMBING - ABOVE CEILING Approved IVRS - Inspection 0000*1.) ALL CORRECTIONS FROM 9/13/01 MADE OK 2.) OK FOR CEILING TILE. 3.) IN THE FUTURE, THE CEILING TILE DOES NOT GO IN UNTIL AFTER YOU RECEIVE INSPECTION.
09/13/2001 PLUMBING - ABOVE CEILING Partial Approval IVRS - Inspection 0000*1.) SUPPORT RECIRCULATION PUMP 2.) REMOVE FLEX FROM T & P R DRAIN AND HARD PIPE WITH UNION 3.) INSTALL UNION DOWN STREAM OF VALVE ON TRAP PRIMER.
09/03/2001 PLUMBING - ABOVE CEILING Not ready for Inspection IVRS - Inspection 0000*1.) PLUMBING ROUGH ON 19TH FLOOR NEEDS TO BE INSPECTED 2.) PLUMBING ABOVE CEILING, NEED TO SEE FINAL N/H CONNECTION COPPER ABOVE CEILING OK 3.) WATER PRESSURE TEST OK N/H IN WALLS OK OK TO COVER WALLS COPPER IN WALLS OK OK TO COVER WALLS. 4.) OK FOR HARD CEILING IN BATHROOM.