Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/17/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/14/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) MECHANICAL IS PARTIALLED FOR DRYER VENT 2) NUMBERS 5, 8 AND 9 NOT DONE |
| 10/10/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) LOOSE RED-HEADS 2) REPLACE OVER NOTCHED STUD ON NORTH GARAGE WALL 3) SHIM BAY HEADER 4) SHIM FRONT DOOR HEADER 5) DRYER VENT RUN TO LONG 6) INCREASE PITCH OF VENT PIPE ABOVE HALL BATH 7) REPAIR HALL BATH LIGHT 8) CORRECT RETURN DUCT KINK OVER MASTER DOOR 9) FILLL SLAB HOLE AT LAUNDRY |
| 10/05/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |