Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM03698

Parcel: 141147870

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/17/2001 FRAMING Approved IVRS - Inspection 0000*
10/14/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) MECHANICAL IS PARTIALLED FOR DRYER VENT 2) NUMBERS 5, 8 AND 9 NOT DONE
10/10/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) LOOSE RED-HEADS 2) REPLACE OVER NOTCHED STUD ON NORTH GARAGE WALL 3) SHIM BAY HEADER 4) SHIM FRONT DOOR HEADER 5) DRYER VENT RUN TO LONG 6) INCREASE PITCH OF VENT PIPE ABOVE HALL BATH 7) REPAIR HALL BATH LIGHT 8) CORRECT RETURN DUCT KINK OVER MASTER DOOR 9) FILLL SLAB HOLE AT LAUNDRY
10/05/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*