Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM03698

Parcel: 141147870

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/02/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/25/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SOLE PLATE PLUMBING CUTS NEED FULLY 2) NAILED FHA STRAPS ON INSIDE AND OUTSIDE
09/19/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NAIL BIRD BOARDS ON SOUTH SIDE OF FRONT DORMER GABLE 2) NO LEDGER IN PLACE AT TOP OF STUB TRUSSES AT FRONT ENTRY 3) FULLY NAIL FHA STRAPS AT SOLE PLATE PLUMBING CUTS
09/14/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) A35'S IMPROPERLY INSTALLED AT FRONT ENTRY LEDGERS 2) STRAP REAR GARAGE WALL TOP PLATES TO GABLE WALL TOP PLATES 3) FHA STRAP BOTTOM PLATES AT PLUMBING CUTS 4) STRAP NORHT WINDOW HEADER 5) TO WET TO MOUNT 6) PLEASE RE-CALL ROOF
09/13/2001 EXT METAL CLIPS/EXT SHEATHING Denied 1) STRAP ALL CORNERS NOT CABIN TIED 2) STRAP HEADER AT GARAGE OPENING 3) STRAP BAY WINDOW 4) PROVIDE CROSS BRACING AT MID-SPAN