Permit: T01CM03693

Parcel: 141147850

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/02/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/25/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) FHA STRAPS NEED TO BE ON INSIDE AND OUTSIDE OF SOLE PLATE CUTS FOR PLUMBING STRAPS ALSO NEED TO BE COMPLETELY NAILED
09/19/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) CONDENSATE LINE IS SHOT WITH NAILS FROM SHEAR PANEL RE-NAIL. REPLACE 2) BLOCK TOP OF LEFT FRONT COLUMN 4) NAIL OFF FHA STRAPS AT PLUMBING AND STRAP INSIDES
09/14/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) RENAIL SHEARWALLS WHERE NAILS SUNK TO DEEP 2) CORRECT AND FINISH FRONT COLUMNS 3) H2.5 PATIO RAFTERS AT HOUSE INTERSECTION 4) STRAP REAR GARAGE WALL TOP PLATES (2 X 6) TO GABLE WALL TOP PLATES 5) FHA STRAP BOTTOM PLATES AT PLUMBING CUTS 6) ROOF NOT DONE-TO WET 7) TO WET TO MOUNT
09/13/2001 EXT METAL CLIPS/EXT SHEATHING Denied 1) STRAP ALL CORNER NOT CABIN TIED 2) STRAP BAY WINDOW 3) BRACE SOUTH WALL 4) MISSING NAILS AT HANGER AT ENTRANCE 5) CROSS BRACE AT MID-SPAN 6) ROOF NAILING-OK