Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/02/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 09/25/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) FHA STRAPS NEED TO BE ON INSIDE AND OUTSIDE OF SOLE PLATE CUTS FOR PLUMBING STRAPS ALSO NEED TO BE COMPLETELY NAILED |
| 09/19/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) CONDENSATE LINE IS SHOT WITH NAILS FROM SHEAR PANEL RE-NAIL. REPLACE 2) BLOCK TOP OF LEFT FRONT COLUMN 4) NAIL OFF FHA STRAPS AT PLUMBING AND STRAP INSIDES |
| 09/14/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) RENAIL SHEARWALLS WHERE NAILS SUNK TO DEEP 2) CORRECT AND FINISH FRONT COLUMNS 3) H2.5 PATIO RAFTERS AT HOUSE INTERSECTION 4) STRAP REAR GARAGE WALL TOP PLATES (2 X 6) TO GABLE WALL TOP PLATES 5) FHA STRAP BOTTOM PLATES AT PLUMBING CUTS 6) ROOF NOT DONE-TO WET 7) TO WET TO MOUNT |
| 09/13/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
1) STRAP ALL CORNER NOT CABIN TIED 2) STRAP BAY WINDOW 3) BRACE SOUTH WALL 4) MISSING NAILS AT HANGER AT ENTRANCE 5) CROSS BRACE AT MID-SPAN 6) ROOF NAILING-OK |