Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/27/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 08/23/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*1.) NAILING SIDING AT 6" ON ALL ENDS AND SUPPORTED EDGES AND 12" IN FIELD. 2.) X BRACE 3 TRUSSES AT EACH END OF ROOF. 3.) TRUSSES MUST BE CONNECTED TO DOUBLE TOP PLATES WITH H 2.5. CLIPS. SEE PAGE 3 4.) HOLD DOWN MISSING BOLTS 5.) SHEATHING ON GABLE AND TRUSSES SPLIT AT DOUBLE TOP PLATES BOTTOM CHORD MUST BE CLIPPED TO WALL AT 32" O.C. 6.) ROOF SHEATING NOT NAILED TO RAKE BOARDS/ FLY RAFTERS. |