Permit: T01CM03626

Parcel: 11307012A


Addresses:

1717 E GLENN ST 02

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
04/11/2002 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*OK WALLS.
04/08/2002 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0935*
04/07/2002 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*NO WORK PROGRESS
03/29/2002 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*1. PLEASE PROTECT NM CABLE WHERE PASSING THROUGH STUDS AS NECESSARY 300-4. 2. WHAT IS STUB FOR W UPSTAIRS ROOM BY TOP OF STAIRS? 3. METAL BOXES NEED TO BE GROUNDED. 4. PLEASE PROVIDE GROUND TAILS WITH SWITCHES DURING ROUGH IN. 5. TIGHTEN CABLE CLAMPS IN BOXES. 6. NM CABLE TO OUTSIDES NEED TO BE STRAPPED WITH 12" OF EXITING. 7. FITTING FOR CABLES ON TOP OF PANELS TO BE TIGHT.