Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/17/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 09/14/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) LEDGERS OVER GARAGE REQUIRE A3 CLIP EVERY OTHER STUD 2) COLUMN MISSING H2.5 CLIPS TOP AND BOTTOM 3) SHEAR WALL NOT NAILED TO STUDS AT 16" ON CENTER NORTH WALL |
| 09/12/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE STRAPS AT BEAMS 2) NAILS MISSING AT HIP TRUSS HANGER 3) NAILS MISSING AT HANGER IN GARAGE |