Permit: T01CM03599

Parcel: 124160190


Addresses:

1250 S EUCLID AV


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T01CM03599

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/05/2002 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000* 1.) CORRECTIONS MADE OK 2.) OK FOR SHEETROCK
03/01/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.)STRAP LOOSE COPPER 2.) ABS HORIZONTAL REQUIRES SUPPORT 4' MAX 3.) INSTALL "DUTCHMAN" ON RECESSED PIPING IN CLOSET BEND. 4.) PROVIDE WATER TEST ON ABS.