Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Partial Approval
Inspection History: FRAMING
Permit Number - T01CM03586
Inspection Description - FRAMING
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/28/2002 | FRAMING | Partial Approval | IVRS - Inspection 0000* | |
02/28/2002 | FRAMING | Approved | IVRS - Inspection 0000*HIT REPAIR IN PORCH AREAS AND PURLINS ON ROOF. |