Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T01CM03581
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/31/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
04/03/2002 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/ 1) WALKED ROOF AND EXTERIOR FRAMED WALLS NAILING-OK 2) NEED REVISED ROOF FRAMING PLAN AND POST FTG. PLAN TO SHOW ALL POST-BEAM FTGS. 3) PLAN TO SHOW ALL BEAMS AND HEADERS SUPPORTING BEAMS 4) COVERING ROOF DECK AND EXTERIOR WALLS SUBJECT TO NEW FRAMING PLAN ANY CHANGES SHOULE BE ABLE TO BE DONE FROM BELOW 5) OK CONDUIT FOR ISLAND COUNTER AND SOIL LINE | |
02/21/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0160*/ 1) PAHD 42 HOLDOWNS HAVE BEEN DEFORMED ( DOG LEG BENT) AT BASE. HAVE ARCHITECT/ENGINEER OF RECORD PROVIDE APPROVED EVALUATION OR REPAIR AS REQUIRED 2) BEDROOM (WEST) ROOF NOT FRAMED PER PLAN BUILD TO PLAN OR REVISE PLAN TO AS BUILT 3) POST FOOTINGS DO NOT EXIST TO BEAR BEDROOM GLUE LAM BEAM 4) HOUSE NOT BUILT TO PLAN. BUILD TO PLAN OR REVISE PLAN TO AS BUILT. NEXT FAILURE WILL BE CHARGED A RE-INSPECTION FEE 5) HAVE PLUMBING PLAN REVISED AND APPROVED TO AS BUILT |