Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM03574

Parcel: 141013890

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/09/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/28/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) HD'S AT GARAGE NOT NAILED TO DOUBLE STUDS 2) CHIMNEY CHASE NOT FRAMED ABOVE 3) COMPLY WITH DETAIL 11-6 4) REVISE PLAN TO SHOW AS BUILT