Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/21/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/18/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) FRAME OK PARTIALLED FOR DRYER VENT ONLY |
| 10/17/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) SHIM THE TOP OF THE TOP SET OF STRINGERS WHERE GAPPED FROM THEIR SUPPORT HEADER 2) OK TO SHEETROCK ALL ELSE (OTHER THAN #1), NOTING THAT DRYER VENT SITUATION MAY REQUIRE CHANGE |
| 10/11/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) CORRECG STAIRS 2) DRYER VENT TO LONG |
| 10/09/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SECURE LINE SET AT GARAGE 2) PROVIDE DETAIL FOR FLOOR TRUSS F AND ADDITIONAL TRUSS AT GARAGE 3) REPLACE ELECTRICAL WIRE AT WEST WALL GARAGE THAT HAS BLACK TAPE WRAPPED AROUND IT 4) COMPLY WITH DETAIL 9-A8 5) PROTECT PLUMBING AT LAUNDRY ROOM 6) FIRE BLOCKING MISSING AT LAUNDRY ROOM 7) STAIRS NOT BUILT PER PLAN 8) SECURE PLUMBING AT SOFFIT FIRST FLOOR 9) BLOCK MECHANICAL 2ND FLOOR FURNACE AREA 10) LEDGE HOLDING TRUSS ABOVE STAIRS IS CRACKED IN HALF LENGTH WISE REPLACE 11) BACKWATER VALVE SHALL BE PROVIDED WITH ACCESS, SEE UPC 1994 CH6 |