Permit: T01CM03570

Parcel: 141147880

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/27/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/26/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SHIM CANTILEVER STUDS/CRIPPLES 2) NAIL OFF PATIO LEDGER H2.5'S 3) NAIL OFF STRAPS AT FRONT BY 4) MAKE POSITIVE CONNECTION AT POP OUT OVER GARAGE
09/25/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) CLIP OR LAY PATIO LEDGER 2) NAIL OFF H2.5'S AT TRUSSES ABOVE KITCHEN SOFFIT 3) NO POSITIVE CONNECTION TO FRONT DORMER POP OUT FRAME 4) MISSED 1 ROW OF NAILS ON PATIOR ROOF 5) STRAP AND CLIP FRONT BAY AREA 6) SHIM HEADERS WHERE NEEDED AND CANTILEVER STUDS/CRIPPLES